1 Press [F], [MENU] and turn the Tuning control to
select Menu No. 8 (SSQ).
2 Press [MENU] and turn the Tuning control to select
“ON” or “OFF” (default).
3 Press [MENU] to store the setting.
The S-meter setting segments appear.
4 Press any key other than [MENU] to exit Menu Mode.
5 Press [F], [REV] to enter S-Meter Level Select Mode.
6 Turn the Tuning control to select your desired level.
7 Press any key other than [ ] (Power) to store the
setting and exit S-Meter Level Select Mode.
SQUELCH HANG TIME
When using S-meter Squelch, you may want to adjust
the time interval between when the received signals drop
and when the squelch closes.
1 Press [F], [MENU] and turn the Tuning control to
select Menu No. 9 (SQH).
2 Press [MENU] and turn the Tuning control to select
from OFF (default), 125, 250, and 500 ms.
3 Press [MENU] to store the setting or any other key to
cancel.
4 Press any key other than [MENU] to exit Menu Mode.
BEEP FUNCTION
The Beep function provides confirmation of entry, error
status, and malfunctions of the transceiver. We
recommend you leave this function ON in order to detect
erroneous operations and malfunctions.
However, to turn the beep function OFF:
1 Press [F], [MENU] and turn the Tuning control to
select Menu No. 24 (BP).
2 Press [MENU] and turn the Tuning control to select
“OFF”.