TK-3202/3206
27
6.VOX 10 TEST CH:Center Power meter ANT
Programming
Writing AG:1kHz/3.0mV Deviation meter SP/MIC connector
Software:KPG-87D
7.
DQT
TEST CH:Center Oscilloscope ANT
Programming
Make the
Balance Adjust
Low AG
Software:KPG-87D
demodulation
[Wide] High AF VTVM wave into
(3 points) square waves
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow] TEST CH:Center
PTT:ON
8.
QT Deviation
TEST CH:Center 0.75kHz ±40Hz
Adjust
Low
[Wide] High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow] TEST CH:Center 0.35kHz ±40Hz
PTT:ON
9.
DQT Deviation
TEST CH:Center 0.75kHz ±40Hz
Adjust
Low
[Wide] High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow] TEST CH:Center 0.35kHz ±40Hz
PTT:ON
10.DTMF Deviation
TEST CH:Center 3.0kHz ±100Hz
Adjust
LPF:15kHz
[Wide] HPF:OFF
PTT:ON
[Narrow] TEST CH:Center 1.5kHz ±100Hz
PTT:ON
11.MSK Deviation
TEST CH:Center 3.0kHz ±100Hz
Adjust
Low
[Wide] High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow] TEST CH:Center 1.5kHz ±100Hz
PTT:ON
ADJUSTMENT
Item Condition
Measurement Adjustment
Specifications/
Test equipment
Terminal Parts Method
Remark