Kenwood TK-2102G User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
TK-2102G
24
ADJUSTMENT
Item Condition
Measurement Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit Parts Method
5. MIC
Sensitivity
[Wide]
1) TEST CH: Center
AG: 1kHz/12mV
PTT: ON
Power
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
TX-RX ANT
SP/MIC
connec-
tor
Check ±2.2kHz~3.8kHz
[Narrow] 2) TEST CH: Center
PTT: ON
±1.1kHz~1.9kHz
6. QT
Deviation
[Wide]
1) TEST CH: High
QT: 67.0Hz
LPF: 3kHz
HPF: OFF
PTT: ON
Power
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
ANT
Program-
ming
software:
KPG-55D
(Windows
version:
ver.4.00
or later)
0.90kHz ±0.03kHz
[Narrow] 2) TEST CH: High
PTT: ON
0.43kHz ±0.03kHz
7. DQT
Deviation
[Wide]
1) TEST CH: High
DQT: D023N
LPF: 3kHz
HPF: OFF
PTT: ON
0.85kHz ±0.03kHz
[Narrow] 2) TEST CH: High
PTT: ON
0.40kHz ±0.03kHz
8. Battery
Warning
Level
1) BATT terminal voltage: 5.8V DVM ANT
BATT
termi-
nal
Adjust the adjust-
ment value until the
LED starts to blink.
The LED must blink.
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 41 42

Comments to this Manuals

No comments